Vertical Autoclave
Silent Features :-
- Fully automatic operation; cycle begins by press of the START button.
- Initial air purging cycle; at the start air is automatically removed from the chamber.
- Microprocessor based digital temperature indicator controller controls temperature /
pressure precisely at set value.
- Temperature sensor: PT 100.
- In built digital timer; timer can be adjusted as per sterilization load requirement.
- Automatic steam exhaust at the end of cycle.
- Low water level heater safeguard.
- Safety high pressure release valve.
- Safety high temperature cut off. Included if ordered separately.
- Outer cover made of stainless steel 1 mm thick.
- Lid, flange & bottom sheet also made of stainless steel. All joints argon welded.
- Joint less silicon gasket. Heavy duty industrial flange heater.
- Pressure range: 15 to 22 PSI, factory set at 15 PSI.
- Temperature range: 121°C to 125°C.
- Temperature resolution: 0.1°C/ temperature accuracy: ±0.5°C.
- Lid fitting pressure gauge 0-30 PSI, safety spring loaded pressure valve, steam release valve.
- Foot lifting arrangement included for size 18"x 24", 18" x 30" & 22" x 30".
- Electrical: 230V /15A / 50 Hz.
- Calibration certificate by ERTL Mumbai with traceability to NPL New Delhi.
Size of Working Chamber |
Capacity |
Rating |
External Dimensions |
Shpg Wt
|
in cmc
Dia x Height |
in Inches
Dia x Height |
Liters |
Kw |
in cms |
in Kgs |
12 x 20 |
30 x 50 |
35 |
2.0 |
75 x 48 x 105 |
60 |
14 x 22 |
35 x 55 |
52 |
3.0 |
48 x 80 x 120 |
80 |
18 x 24 |
45 x 60 |
95 |
4.0 |
70 x 90 x 135 |
110 |
18 x 30 |
45 x 75 |
125 |
4.0 |
70 x 90 x 145 |
135 |
22 x 30 |
55 x 75 |
175 |
6.0 |
85 x 110 x 145 |
140 |
Optional Extras / Accessories
- Digital high temp. Safety controller cum indicator which can be set 2°C above the set temperature for safety purposes and will cut-off the heater with audio-visual alarm ensuring temperature within chamber doesn't exceed safety threshold.
- Printer interface facility to record data of 1 temperature and 1 pressure location within the chamber, can print date, time, temperature when connected to EPSON LX 300 Dot matrix printer. (Not supplied with printer)
- Printer interface facility to record data of 3 temperature and 1 pressure location within the chamber, can print date, time, temperature when
connected to EPSON LX 300 Dot matrix printer. (Not supplied with printer)
- PC interface with software
- 24 column printer (Imported) to be connected to above printer interface
- Do with FO indication with standard PC software. (Not supplied with printer)
- Basket made of thick SS wire mesh rods.
Temperature Mapping / Validation
Autoclave : Performance qualification with temperature mapping on site.
Temperature mapping consist of totally six cycles. Three cycles to demonstrate the uniformity of temperature within empty chamber, and the other three cycles in loaded chamber condition. This is done to demonstrate that temperature distribution in the loaded chamber is acceptable and that the items within the chamber receive a uniform heat treatment.
Data is collected in printed format from up to six different points within the chamber.
Temperature uniformity is considered acceptable if the deviation is ±1°C of set sterilization temperature.
STD MODEL |
GMP MODEL |
1) Outer cabinet mild steel powder coated. |
1) Inner chamber stainless steel 304 grade. |
2) Inner chamber stainless steel SS 304 grade. |
2) Inner chamber stainless steel mirror finish |
We provide DQ, IQ, OQ, PQ documentation. |
|